Please contact Schneider Electric SCADA Global Support if you require assistance or advice regarding this procedure. Important Note: Please do not restore your old backed-up Tagdriv.ini file. If you have a modified Tagdriv.ini file, you will need to edit the new Tagdriv.ini file to get your changes back. The recommended upgrade procedure is to backup Tagdriv.ini before installing V7.10 Service Pack 4. Tagdriv.ini file change The Tagdriv.ini file was necessarily modified in V7.10 Service Pack 4. Important Note: Please do not restore your old backed-up m file or you will get errors in your project. If you have a modified m file, you will need to edit the new m file to get your changes back. The recommended upgrade procedure is to backup all project files (including the m file) before installing V7.10 Service Pack 4. This caused issues for some users who had modified their m file previously. Lastly, restore your projects and recompile to run on Windows 7.Ĭm file change The m file was necessarily modified in V7.10 Service Pack 2. After installing the product, please install V7.10 Service Pack 4 to ensure Windows 7 compatibility. Updated drivers stamped for Windows 7 are available for download from our DriverWeb website. Ignore any warnings that drivers may not be compatible with Windows 7 - the majority of the drivers have been tested and will function correctly. To run on Windows 7, please install your SCADA product using your product DVD. Windows 7 Compatibility The application of the V7.10 Service Pack 4 will allow users to run the product on the Windows 7 operating system. Customers should also do an Update Pages (in Graphics Builder→Tools→Update Pages) on any projects using CSV_Include templates. Ensure that the Incremental Compile menu option (in Project Editor→Tools→Options) is not checked, or set INCREMENTALCOMPILE=0. To force an upgrade, edit the Citect.ini file and set UPGRADE=1. Failure to do so will result in conflicting database size messages. Important: All projects must be upgraded and recompiled after installing this Service Pack. Important: As per recommended practice, all projects should be backed up prior to commencing the Service Pack installation. CitectSCADA 7.10 Release Notes for Service Pack 4 The V7.10 Service Pack 4 includes several product updates and enhancements, providing improvements in stability, performance and functionality.
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |